Migibio
Migi (Dog) CDV-AgCanine Distemper Virus Antigen Rapid Quantitative Test Kit

Migi (Dog) CDV-AgCanine Distemper Virus Antigen Rapid Quantitative Test Kit

Catalog No.: MG-CA-R004

Migi (Dog) CDV-AgCanine Distemper Virus Antigen Rapid Quantitative Test Kit — a quantitative fluorescence immunochromatography (FICT) rapid test for canine diagnostics, delivering results in minutes with pg/ml-level sensitivity. CE/ISO9001-compliant manufacturer. Cat. No. MG-CA-R004.

Catalog Number: MG-CA-R004

TL;DR — The CDV-AgCanine Distemper Virus Antigen is a quantitative fluorescence immunoassay used with a Migibio Immunofluorescence Analyzer. It ships as a 10-test/box kit, a 2-year shelf life, an MOQ of 10 boxes, and a 10-minute Quick Test result. For clinical interpretation, see Distemper Tests for Dogs: Antigen vs Antibody Results.

Applications & Who It’s For

  • Veterinary clinics & animal hospitals — same-visit quantitative CDV-AgCanine Distemper Virus Antigen results to support diagnosis and case management.
  • Shelters & catteries — intake screening and early detection and outbreak monitoring where CDV-AgCanine Distemper Virus Antigen is part of the admission panel.
  • Breeders & kennels — monitor infection or immunity status in breeding and boarding groups.
  • Reference labs & multi-vet hospitals — batch multiple devices on the analyzer for high-throughput reporting.

See also: Distemper Tests for Dogs: Antigen vs Antibody Results.

FAQ

Which analyzer does this run on?

It is used with a Migibio Immunofluorescence Analyzer; follow the analyzer operation manual.

What is the MOQ and shelf life?

The listed MOQ is 10 boxes; shelf life is 2 years.

What sample does it use?

The test can be performed using a nasopharyngeal or ocular swab.

Product Specifications

AttributeValue
Place of OriginChina
CAT No.MG-CA-R004
PackageBox
AppearanceLiquid
Specification10T
StorageRoom Temperature
Shelf life2 years
MOQ10 boxes
Suitable forVeterinary
GradeReagent Grade

Specification

10 Tests/Box Cat. No.: MG-CA-R004

Intended Use

The CDV-Ag test is a fluorescence immunoassay designed for use with an Immunofluorescence Analyzer to quantitatively measure distemper virus antigen (CDV-Ag) in canine nasopharyngeal or ocular swabs. It is used to aid in diagnosing and monitoring canine distemper virus infections. For in vitro diagnostic use only. For professional use only.

Clinical Significance

Canine distemper virus (CDV) causes severe multisystemic disease with high mortality, particularly in unvaccinated puppies. Early antigen detection is critical for prompt diagnosis and isolation.

Quantitative CDV antigen testing supports rapid confirmation of infection during outbreaks and guides appropriate supportive and containment measures.

Test Principle

This test uses a quantitative double antibody sandwich fluorescence immunoassay technique. The intensity of the fluorescent signal reflects the amount of CDV-Ag captured, with the concentration expressed as Tu/ml.

Materials

Materials Provided Each box contains: 10 individual sealed pouches, each containing: Test Device Desiccant pouch 1 ID Chip Instructions for Use 10 cotton swabs 10 tubes of CDV-Ag Sample Buffer 10 Pipette Tips Materials Required but Not Provided Immunofluorescence Analyzer Timer Pipette Centrifuge

Storage and Stability

Store the test kit between 4°C and 30°C until the expiration date. After opening the Test Device, operate the test between 18°C and 28°C. Perform the test within 30 minutes of opening the pouch.

Specimen Collection and Preparation

The test can be performed using a nasopharyngeal or ocular swab. Sample collection: Gently swab the canine’s nasopharyngeal or ocular (conjunctival) area to collect a sample. Perform the test immediately after collection. If the test cannot be performed within 3 hours, store the sample at 2°C to 8°C for no more than 48 hours. For long-term storage, freeze at -20°C or lower. Bring all materials to room temperature before testing. Thaw frozen specimens completely and mix well. Avoid repeated freeze-thaw cycles.

Test Procedure

Refer to the Immunofluorescence Analyzer Operation Manual for detailed instructions. Place the Test Device on a clean, level surface. Insert the ID Chip into the analyzer and verify that the Test Device lot number matches the ID Chip. Place the swab with the sample into the CDV-Ag Sample Buffer, stir thoroughly, and centrifuge for 1 minute (3,000–5,000 rpm). Pipette 100 μl of the mixed sample into the sample well (S) of the Test Device, avoiding bubbles. Test Mode Options: a) Standard Test: Select “Standard Test,” insert the Test Device into the meter after adding the sample, and click “Start Test.” Select the sample type “Nasopharyngeal/Ocular Swab.” The meter will automatically read and display the result. b) Quick Test: Select “Quick Test,” start the timer after adding the sample, and allow the Test Device to sit at room temperature for 10 minutes. Then insert the Test Device into the meter and click “Start Test.” Select “Nasopharyngeal/Ocular Swab” as the sample type. Results will be displayed on the main screen and printed automatically or manually by selecting “Print.”

Quality Control

Each CDV-Ag Rapid Quantitative Test includes an internal control for routine quality checks. If the internal control fails, the meter will display an error message, indicating that a new test should be performed.

Interpretation of Results

Detection range:

  • 4.0 ~ 640 Tu/ml Reference range: ≤8 Tu/ml: Negative (-) 8–15 Tu/ml: Suspected (±) 15–40 Tu/ml: Weak Positive (+) 40–200 Tu/ml: Medium Positive (++) 200 Tu/ml: Strong Positive (+++) Each laboratory should establish a reference range suited to the population being tested.

Warnings and Limitations

For in vitro diagnostic use only. Inspect packaging and labels before use. Do not use if the pouch is damaged or the vial is leaking. Do not use the Test Device beyond the expiration date. Use a separate pipette tip for each specimen. Factors such as technical or procedural errors, and substances not listed, may interfere with results.